FlexADOS 914
Multi-channel gas warning controller for up to 12 transmitters (4–20 mA). Three alarm thresholds per sensor, 14 alarm relays plus fault relay, optional Modbus RTU/TCP or Profibus. SIL1 with GTR 210, IP 54.
ADOS GmbH of Aachen, Germany, has built gas measurement equipment since 1900, when it introduced its first automatic flue gas monitor. Today ADOS develops and manufactures gas warning controllers, gas transmitters and gas analysers for industry, utilities and laboratories.
Verdant Technik supplies, installs and services ADOS systems in the Philippines, so your gas detection is designed, commissioned and calibrated by a local team.
Official distributor in the Philippines. Contact us for specifications, pricing and lead times.
Multi-channel gas warning controller for up to 12 transmitters (4–20 mA). Three alarm thresholds per sensor, 14 alarm relays plus fault relay, optional Modbus RTU/TCP or Profibus. SIL1 with GTR 210, IP 54.
Gas warning unit for 19" rack, panel or wall mounting, up to 10 units per rack. Three alarm levels, 4–20 mA output and RS 232/485. Covers 19 gases including CO, CO₂, CH₄, NH₃, H₂, O₂, propane and butane.
Request specs →16-channel gas warning unit with up to 48 relay outputs, horn and warning-banner relays. Ranges include CH₄, LPG and H₂ 0–100% LEL, NH₃, CO, NO₂, CO₂ and O₂.
Request specs →Compact 8-channel gas warning unit with two alarm thresholds per sensor and RS 232 data logging for CO, NO₂, CH₄ and CO₂.
Request specs →Small gas warning unit for up to six 2-wire or three 3-wire sensors, with three alarm relays and fault relay.
Request specs →Industrial and explosion-proof (ATEX II 2G) gas transmitter with five sensor principles: semiconductor, catalytic, electrochemical, infrared and PID. Combustibles up to 100% LEL plus O₂, CO, NH₃, NO₂, SO₂, H₂S and CO₂.
Ex gas transmitter (ATEX / IECEx, SIL1) with catalytic, infrared, electrochemical or PID sensors for combustible gases, O₂, CO₂, H₂S, refrigerants and VOCs. IP 66/67.
Cost-effective combustible gas transmitter for gas-fired boiler houses, gas distribution and transfer stations, and battery charging rooms. Semiconductor, catalytic or infrared sensor.
Request specs →Electrochemical 2-wire transmitter for toxic gases: CO, NH₃, NO₂, SO₂, H₂S and O₃, ranges from 0–20 ppm to 0–5,000 ppm.
Request specs →Continuous CO, CO₂ and O₂ analysis of boiler flue gas and process exhaust, with a self-regenerating double filter for dusty or corrosive gas.
Multi-channel biogas analyser for up to 5 biogas and 3 room sensors: CH₄, CO₂, O₂, H₂S and H₂. 16 configurable alarms, 4–20 mA outputs and RS 232/485.
Cabinet biogas analyser with Peltier gas cooling and condensate pump for wet biogas, up to six channels, continuous or intermittent measurement.
Request specs →Optical dust monitor on the clean-air side of fine dust filters, so a filter breakdown is detected at once (0.1–100 mg/m³).
Request specs →Standard and Ex alarm horns up to 108 dB(A), LED signal towers, rotating and flashing lamps, and illuminated warning banners.
Request specs →Test gas bottles and pressure reducers for zero and span checks of gas transmitters.
Request specs →Battery stand-by supply that keeps gas warning controllers running through power outages.
Request specs →Stainless steel housings (V2A / V4A) for transmitters in tunnels, offshore and harsh outdoor areas.
Request specs →Product information from ados.de, for reference only. Specifications depend on sensor type and range; ask us for the datasheet of the exact model.
Combustible gas leak detection around gas-fired boilers, gas trains and flue gas monitoring.
Explosion protection with Ex-rated transmitters for hydrocarbons, H₂S and solvents.
H₂S, CH₄, CO₂ and O₂ monitoring in sewage plants, digesters and biogas CHP.
CO₂ and O₂ measurement in fermentation, bottling and cellar areas.
NH₃, CO₂ and refrigerant leak detection in cold stores and chiller plants.
Toxic gas and oxygen monitoring to protect people in labs, test stands and plant rooms.
The full ADOS service scope, delivered locally by Verdant Technik engineers.
Gas risk review, sensor selection and placement, and alarm concept for your plant.
Start-up, adjustment, documentation and operator training by our local engineers.
Periodic calibration with test gas, inspections, repairs and spare sensors, backed by ADOS Germany.
Tell us the gases, area and hazard zone. We'll design an ADOS gas warning system for your site.