Germany · Since 1900

Gas analysis and gas warning technology

ADOS GmbH of Aachen, Germany, has built gas measurement equipment since 1900, when it introduced its first automatic flue gas monitor. Today ADOS develops and manufactures gas warning controllers, gas transmitters and gas analysers for industry, utilities and laboratories.

Verdant Technik supplies, installs and services ADOS systems in the Philippines, so your gas detection is designed, commissioned and calibrated by a local team.

Combustible gases (LEL)Toxic gasesOxygenATEX / IECExSIL1
ADOS logo

ADOS product range

Official distributor in the Philippines. Contact us for specifications, pricing and lead times.

Request a quote →

Gas warning controllers

FlexADOS 914

Multi-channel gas warning controller for up to 12 transmitters (4–20 mA). Three alarm thresholds per sensor, 14 alarm relays plus fault relay, optional Modbus RTU/TCP or Profibus. SIL1 with GTR 210, IP 54.

CH₄H₂H₂SCO₂O₂
Request specs →

GW 399

Gas warning unit for 19" rack, panel or wall mounting, up to 10 units per rack. Three alarm levels, 4–20 mA output and RS 232/485. Covers 19 gases including CO, CO₂, CH₄, NH₃, H₂, O₂, propane and butane.

Request specs →

MWS 906

16-channel gas warning unit with up to 48 relay outputs, horn and warning-banner relays. Ranges include CH₄, LPG and H₂ 0–100% LEL, NH₃, CO, NO₂, CO₂ and O₂.

Request specs →

MWS 903

Compact 8-channel gas warning unit with two alarm thresholds per sensor and RS 232 data logging for CO, NO₂, CH₄ and CO₂.

Request specs →

MWS 897

Small gas warning unit for up to six 2-wire or three 3-wire sensors, with three alarm relays and fault relay.

Request specs →

Gas transmitters & sensors

GTR 196

Industrial and explosion-proof (ATEX II 2G) gas transmitter with five sensor principles: semiconductor, catalytic, electrochemical, infrared and PID. Combustibles up to 100% LEL plus O₂, CO, NH₃, NO₂, SO₂, H₂S and CO₂.

Ex d4–20 mA
Request specs →

GTR 210

Ex gas transmitter (ATEX / IECEx, SIL1) with catalytic, infrared, electrochemical or PID sensors for combustible gases, O₂, CO₂, H₂S, refrigerants and VOCs. IP 66/67.

IECExSIL1
Request specs →

LCTR 903

Cost-effective combustible gas transmitter for gas-fired boiler houses, gas distribution and transfer stations, and battery charging rooms. Semiconductor, catalytic or infrared sensor.

Request specs →

TOX 592

Electrochemical 2-wire transmitter for toxic gases: CO, NH₃, NO₂, SO₂, H₂S and O₃, ranges from 0–20 ppm to 0–5,000 ppm.

Request specs →

Flue gas, biogas & dust analysis

RG 399 flue gas analyser

Continuous CO, CO₂ and O₂ analysis of boiler flue gas and process exhaust, with a self-regenerating double filter for dusty or corrosive gas.

BoilersProcess gas
Request specs →

Biogas 905

Multi-channel biogas analyser for up to 5 biogas and 3 room sensors: CH₄, CO₂, O₂, H₂S and H₂. 16 configurable alarms, 4–20 mA outputs and RS 232/485.

DigestersBiogas CHP
Request specs →

Biogas 401

Cabinet biogas analyser with Peltier gas cooling and condensate pump for wet biogas, up to six channels, continuous or intermittent measurement.

Request specs →

Filter-Guard 206

Optical dust monitor on the clean-air side of fine dust filters, so a filter breakdown is detected at once (0.1–100 mg/m³).

Request specs →

Alarm & system accessories

Alarm horns, lamps & warning banners

Standard and Ex alarm horns up to 108 dB(A), LED signal towers, rotating and flashing lamps, and illuminated warning banners.

Request specs →

Test gas & calibration kits

Test gas bottles and pressure reducers for zero and span checks of gas transmitters.

Request specs →

UPS 2000 stand-by power

Battery stand-by supply that keeps gas warning controllers running through power outages.

Request specs →

Protection housings

Stainless steel housings (V2A / V4A) for transmitters in tunnels, offshore and harsh outdoor areas.

Request specs →

Product information from ados.de, for reference only. Specifications depend on sensor type and range; ask us for the datasheet of the exact model.

Applications in the Philippines

Where ADOS keeps plants safe

Boiler houses & burners

Combustible gas leak detection around gas-fired boilers, gas trains and flue gas monitoring.

Refineries, chemicals & LPG storage

Explosion protection with Ex-rated transmitters for hydrocarbons, H₂S and solvents.

Wastewater & biogas

H₂S, CH₄, CO₂ and O₂ monitoring in sewage plants, digesters and biogas CHP.

Food, beverage & breweries

CO₂ and O₂ measurement in fermentation, bottling and cellar areas.

Cold storage & refrigeration

NH₃, CO₂ and refrigerant leak detection in cold stores and chiller plants.

Laboratories & workplace safety

Toxic gas and oxygen monitoring to protect people in labs, test stands and plant rooms.

Services

From design to calibration

The full ADOS service scope, delivered locally by Verdant Technik engineers.

Consultation & system design

Gas risk review, sensor selection and placement, and alarm concept for your plant.

Installation & commissioning

Start-up, adjustment, documentation and operator training by our local engineers.

Calibration & maintenance

Periodic calibration with test gas, inspections, repairs and spare sensors, backed by ADOS Germany.

Need gas detection for your plant?

Tell us the gases, area and hazard zone. We'll design an ADOS gas warning system for your site.

Request a quote →